OPERATION & MAINTENANCE...


Click here to download a condensed PDF manual.


DAILY USE

  1. Before each use place a new bowl liner into toilet bowl.
  2. After using the toilet "flush" liner and waste into incinerator chamber by stepping on the foot pedal. Allow liner to fall completely into the incinerator, then release foot pedal.
  3. Push start button at back of toilet to start an incineration cycle. This is required even if the toilet is operating from a previous use.
  4. Note: INCINOLET can be used anytime - even during incineration of a previous cycle. Just follow the above steps.



WEEKLY, OR MORE OFTEN AS REQUIRED

  1. Empty the ashpan at regular intervals (perhaps once or twice a week). Ash should not accumulate more than one-half inch.
  2. Clean outer stainless steel surfaces including bowl halves with detergent and water or stainless steel polish. Do not hose down or steam clean the toilet. Keep bowl halves clean to prevent liners from sticking.

EVERY 90 DAYS, DEPENDING ON USAGE
(OR IF EXCESSIVE NOISE OR VIBRATION OCCURS)

  1. DISCONNECT TOILET FROM SOURCE OF ELECTRICITY.
  2. Remove top of the toilet complete with the bowl sections by removing four screws and unscrewing the rubber pushbutton cover.
  3. Clean interior of bits of paper and dust.
  4. Lightly grease all moving joints of the flushing assembly and foot pedal.
  5. Clean the blower assembly by removing three screws which hold blower motor in position. Lift out the motor with attached blower wheel. Turn the assembly to one side to clean the blower wheel, using a small brush. Replacement of an extremely dirty or corroded blower wheel helps eliminate noise, rattles and vibration. Clean inside the blower housing and ventline elbow as needed.6. Replace the unit top while holding bowl halves together. Replace four screws, and protective cap on the start switch.

YEARLY

  1. Inspect the level of catalyst. If low, add additional catalyst.